Find out how many soffit vents and how much ridge vent your attic needs. Enter the attic size to get the ventilation area, the length or count of vents, and a balanced intake and exhaust split.
Last updated 4 November 2026. Based on the IRC R806 ventilation rules and typical vent data. Always check your local code and the product label.
Four steps and no sign-up. Quick mode gives the vent area and quantity from the attic size alone. Advanced adds stock lengths, waste, prices and an attic size helper.
Multiply the length by the width of the attic floor. Use the area of the vented attic space, not the roof surface. A 30 x 40 ft house has about 1,200 ft².
Use 1:150 as the standard rule. Use 1:300 only where your code allows it. Keep the 60/40 split for more intake than exhaust, or pick another.
Choose a soffit vent and a ridge or roof vent. Enter the net free area (NFA) printed on each product label for an exact result.
Get the area, the length or count of each vent, the installed ratio and a fit check against your eave and ridge length. Add prices for a cost estimate.
Most vent calculators stop at a single count. This one sizes both sides of the system, rounds to real product lengths and checks that the answer fits your roof.
Splits the required area into intake and exhaust, then sizes soffit vent and ridge or roof vent separately, including the length of ridge vent.
Continuous vents are rounded up to stock pieces. Individual vents are rounded up to whole vents. The installed ratio is shown after rounding.
Warns when the 1:300 conditions are not met, when exhaust exceeds intake, or when a vent will not physically fit on your eave or ridge.
Enter eave and ridge length to see vent spacing and how much of the eave or ridge the vent needs.
Compare 1:150 with 1:300, different intake splits, attic sizes and vent ratings side by side.
Use the IRC floor-area rule in feet or metres, or switch to the UK eaves rule for tile vents. Cost, waste and a diagram are included.
The answer depends on the size of the attic and the vent products you choose. Building codes set the total net free ventilating area (NFA), which is the open area that air can actually pass through. Soffit vents supply the intake and ridge or roof vents provide the exhaust. For a typical 1,200 ft² attic the standard 1:150 rule needs 1,152 in² of NFA, which is about 76.8 ft of 2-inch soffit strip at 9 in² per foot plus 25.6 ft of high-flow ridge vent at 18 in² per foot, with a 60/40 split.
| Step | 1:150 rule | 1:300 rule |
|---|---|---|
| Total NFA | 1,200 x 144 / 150 = 1,152 in² (8.00 ft²) | 1,200 x 144 / 300 = 576 in² (4.00 ft²) |
| Soffit intake (60%) | 691.2 in² | 345.6 in² |
| Ridge exhaust (40%) | 460.8 in² | 230.4 in² |
| Soffit strip at 9 in² per ft | 76.8 ft (38.4 ft per eave) | 38.4 ft (19.2 ft per eave) |
| Ridge vent at 18 in² per ft | 25.6 ft | 12.8 ft |
| Ridge vent at 12 in² per ft | 38.4 ft | 19.2 ft |
The International Residential Code (IRC) section R806 sets the minimum net free ventilating area for vented attics at 1/150 of the area of the vented space. A reduced ratio of 1/300 is allowed when specific conditions are met.
| Ratio | When it applies |
|---|---|
| 1:150 | The default rule. Use it whenever you are unsure. |
| 1:300 | Allowed where a Class I or II vapor retarder is installed on the warm-in-winter side of the ceiling in climate zones 6, 7 and 8, and/or where 40% to 50% of the required area is in upper vents placed no more than 3 ft below the ridge, with the rest at the eaves. The exact wording differs between code editions. |
Ventilation works because cool air enters low at the soffits and warm air leaves high at the ridge. The two sides need to be balanced:
| Intake / exhaust | Soffit NFA | Ridge NFA | Soffit strip (9 in² per ft) | Ridge vent (18 in² per ft) |
|---|---|---|---|---|
| 50 / 50 | 576.0 in² | 576.0 in² | 64.0 ft | 32.0 ft |
| 60 / 40 | 691.2 in² | 460.8 in² | 76.8 ft | 25.6 ft |
| 65 / 35 | 748.8 in² | 403.2 in² | 83.2 ft | 22.4 ft |
| 70 / 30 | 806.4 in² | 345.6 in² | 89.6 ft | 19.2 ft |
NFA is the open area of a vent after the louvers, screens and baffles are taken out. A vent that looks 16 inches wide may have far less open area than you expect. Always use the NFA printed on the product label, not the size of the vent. The values below are typical starting points only.
| Vent type | Role | Typical NFA |
|---|---|---|
| Continuous soffit strip (2 in) | Intake | About 9 in² per linear ft |
| Individual louvered soffit vent | Intake | Roughly 20 to 65 in² each, depending on size |
| Ridge vent, standard | Exhaust | About 9 to 12 in² per linear ft |
| Ridge vent, high-flow | Exhaust | Up to about 18 in² per linear ft |
| Static box roof vent | Exhaust | Roughly 50 to 60 in² each |
| Gable louver, turbine, power fan | Exhaust | Rated per product. Read the label. |
This table uses a 60/40 split, 2-inch soffit strip at 9 in² per foot and high-flow ridge vent at 18 in² per foot.
| Attic floor area | NFA at 1:150 | NFA at 1:300 | Soffit strip (1:150) | Ridge vent (1:150) | Ridge vent (1:300) |
|---|---|---|---|---|---|
| 600 ft² | 576 in² | 288 in² | 38.4 ft | 12.8 ft | 6.4 ft |
| 800 ft² | 768 in² | 384 in² | 51.2 ft | 17.1 ft | 8.5 ft |
| 1,000 ft² | 960 in² | 480 in² | 64.0 ft | 21.3 ft | 10.7 ft |
| 1,200 ft² | 1,152 in² | 576 in² | 76.8 ft | 25.6 ft | 12.8 ft |
| 1,500 ft² | 1,440 in² | 720 in² | 96.0 ft | 32.0 ft | 16.0 ft |
| 1,800 ft² | 1,728 in² | 864 in² | 115.2 ft | 38.4 ft | 19.2 ft |
| 2,000 ft² | 1,920 in² | 960 in² | 128.0 ft | 42.7 ft | 21.3 ft |
| 2,500 ft² | 2,400 in² | 1,200 in² | 160.0 ft | 53.3 ft | 26.7 ft |
| 3,000 ft² | 2,880 in² | 1,440 in² | 192.0 ft | 64.0 ft | 32.0 ft |
Spread soffit vents along both eaves rather than grouping them. Place continuous strips or louvers as far out toward the fascia as possible so air reaches the whole underside of the roof, and keep every rafter bay open. For individual soffit vents, the spacing is the eave length divided by the number of vents. Enter your eave length and the calculator gives the centre-to-centre distance.
The number of individual vents depends heavily on the NFA of each one. For the 1,200 ft² attic at 1:150 and a 60/40 split, the soffit side needs 691.2 in²:
| NFA per soffit vent | Vents needed | Spacing along 60 ft of eaves |
|---|---|---|
| 20 in² | 35 | 1.7 ft |
| 30 in² | 24 | 2.5 ft |
| 40 in² | 18 | 3.3 ft |
| 50 in² | 14 | 4.3 ft |
| 60 in² | 12 | 5.0 ft |
Ridge vent length = exhaust NFA needed / NFA per foot of the product. A higher-rated product means less length. The ridge must be long enough to take it, and you need to stop short of the ends. If the ridge is too short, add roof vents or choose a high-flow ridge vent.
| Ridge vent NFA | Length at 1:150 (40% exhaust) | Length at 1:300 (40% exhaust) |
|---|---|---|
| 9 in² per ft | 51.2 ft | 25.6 ft |
| 12 in² per ft | 38.4 ft | 19.2 ft |
| 15 in² per ft | 30.7 ft | 15.4 ft |
| 18 in² per ft | 25.6 ft | 12.8 ft |
The UK approach, as commonly summarised from BS 5250 and Approved Document C, sizes the opening along the eaves rather than the floor area. For roofs at 15 degrees or steeper a continuous 10 mm opening is used (10,000 mm² per metre of eaves), and for lower pitches a 25 mm opening (25,000 mm² per metre). Ridge ventilation of 5,000 mm² per metre is added where the pitch is over 35 degrees or the span is 10 m or more. Switch the calculation method to UK to use it with tile vents.
In cold climates, ventilation helps keep the roof deck cold so snow melts less unevenly, which reduces ice dams, and it carries away moisture that leaks into the attic. In hot climates it lowers attic heat. In both, the biggest wins come from air sealing and insulation at the attic floor. Ventilation alone does not fix a leaky ceiling.
Unvented attics, where insulation such as spray foam is applied at the roof deck, have no soffit or ridge vents. They follow a different section of the code and different rules. This calculator is for vented attics. If your roof is an unvented or conditioned assembly, follow the insulation manufacturer and your local code.
The calculation follows the net free ventilating area rules of IRC section R806. The ratios, the 40% to 50% upper-vent condition, the 3 ft placement, the 1 inch clearance and the 1/16 to 1/4 inch opening size were checked against the ICC code change document for IRC R806 on 4 November 2026. The intake and exhaust balance guidance was checked against Penn State PHRC attic ventilation guidance and the Benjamin Obdyke net free area guide. Code editions are revised often, so confirm the current requirement with your local building department.
More Kalikolom construction tools: the Concrete Driveway Calculator, the Concrete Post Hole Calculator, the Concrete Weight Calculator and the Gravel Calculator. Browse all Kalikolom tools.
It depends on the attic size, the ratio and the NFA of your vent. For a 1,200 ft² attic at 1:150 with a 60/40 split, the soffit side needs 691.2 in² of NFA. That is about 76.8 ft of 2-inch soffit strip at 9 in² per foot, or 18 individual vents rated at 40 in² each. Enter your own numbers above.
Multiply the attic floor area in square feet by 144 and divide by 150 (or 300 where allowed). The result is the total net free area in square inches. Then split it between intake at the soffits and exhaust at the ridge or roof, and divide each by the NFA of the vent product to get the length or number of vents.
The 1/150 rule requires 1 square foot of net free ventilating area for every 150 square feet of vented attic space. It is the default rule in the IRC. A 1,200 ft² attic therefore needs 8 ft², or 1,152 in², of NFA.
The 1/300 rule halves the vent area. It is allowed only when conditions are met, such as a Class I or II vapor retarder on the warm side of the ceiling in climate zones 6 to 8, and/or 40% to 50% of the vent area high in the attic within 3 feet of the ridge. The wording differs between code editions, so confirm with your local building department. If you are unsure, use 1/150.
Net free area is the open area of a vent that air can pass through, after louvers, screens and baffles are taken out. It is printed on the product label or data sheet. Two vents of the same size can have very different NFA, so always use the label value.
It depends on the product. A 2-inch continuous soffit strip is commonly listed at about 9 in² per linear foot. Individual louvered soffit vents vary widely, roughly 20 to 65 in² each. Use the figure on your product label and enter it in the calculator.
Divide the exhaust NFA needed by the NFA per foot of the ridge vent. For a 1,200 ft² attic at 1:150 and a 60/40 split, the exhaust side needs 460.8 in². A high-flow ridge vent at 18 in² per foot needs about 25.6 ft, and a standard ridge vent at 12 in² per foot needs about 38.4 ft.
At 1:150 and a 60/40 split the attic needs 1,440 in² of NFA. The soffit side takes 864 in², which is 96.0 ft of 9 in² per foot strip, or about 48.0 ft along each eave. The ridge side takes 576 in², about 32.0 ft of 18 in² per foot ridge vent.
At 1:150, a 2,000 ft² attic needs 1,920 in² (13.3 ft²) of NFA. With a 60/40 split that is 128.0 ft of soffit strip at 9 in² per foot and 42.7 ft of ridge vent at 18 in² per foot.
Intake should be equal to or greater than exhaust. A 50/50 split is the code baseline, and many installers use 60/40 or up to about 70/30 in favour of intake. Under the 1:300 option, 40% to 50% of the area is exhaust.
Yes. A ridge vent only exhausts air. Without intake at the soffits, it has nothing to draw, and it may pull air from the house instead. The intake side should be at least equal to the exhaust side.
It is best not to mix different types of exhaust vents. Air can enter one exhaust vent and leave another, short-circuiting the flow so the soffits do not draw air. Use one type of exhaust and put the intake at the eaves.
Space them evenly along both eaves, with one in every few rafter bays for individual vents. The spacing is the eave length divided by the number of vents. Enter your total eave length in the calculator to get the centre-to-centre distance.
Not always. The attic floor area is the area of the vented space under the roof. For a simple one-storey house it is close to the footprint, but garages, porches and separate roof sections are different. Each separately vented attic needs its own calculation.
Codes call for an air space, commonly about 1 inch, between the insulation and the roof sheathing so air can flow from the soffit upward. Install baffles at each rafter bay to hold the insulation back.
More vent area than the minimum does not usually harm, but exhaust above intake is a problem because it can pull conditioned air from the house. Keep intake equal to or greater than exhaust, and seal air leaks in the ceiling.
No. An unvented or conditioned attic, where insulation is applied at the roof deck, follows different code rules and does not use soffit or ridge vents. Follow the insulation manufacturer and your local code. This calculator is for vented attics.
Often not on its own. The holes in perforated soffit panels may not provide enough NFA, and some local inspectors do not count them. Check the product's rated NFA, and add continuous strip or louvered vents where needed.
The UK approach sizes the eaves opening. As commonly summarised, it is 10,000 mm² per metre of eaves for pitches of 15 degrees or more, and 25,000 mm² per metre below that. Ridge ventilation of 5,000 mm² per metre is added for pitches over 35 degrees or spans of 10 m or more.
Yes. Switch the units to metric to enter areas in square metres, lengths in metres and vent ratings in cm² per metre or cm² per vent. The result is the same as in US units.
Vents are sold in whole pieces, so the installed area is a little more than the need. The installed ratio is the actual ratio after rounding up. It should be equal to or better than your target.
The maths is exact for the inputs. Accuracy depends on using the real NFA from your product label, the right attic area and the ratio your code allows. Treat it as a planning and ordering aid and confirm with your local building department.
It depends on where you live and what you are changing. Re-roofing and structural changes often need a permit, and inspectors may check ventilation. Ask your local building department.